Rated Voltage :0.6 / 1kV
Conductor :Bear Copper
No. Of Cores :3 Cores
Insulation :XLPE compound
Armoured Type :Unarmoured
Sheath :PVC Compound
Contact Now

Add to Cart

Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
View Product Description

IEC 60502-1 Cables

600/1000V, XLPE Insulated Cables according to IEC 60502-1

Applications

These cables are used for electricity supply in low voltage installation system, They are suitable for installation in indoors and outdoors, in cable ducts, under ground, in power and switching stations, local energy distributions, industrial plants, where there is no risk of mechanical damage.

Construction

1. Conductors

------------------------------------------------------------------------------------------------------

The conductors shall be either of Class 1 or Class 2 of plain or metal-coated annealed copper or of plain aluminium or aluminium alloy, or of Class 5 of plain or metal-coated copper in accordance with IEC 60228.
2. Insulation

------------------------------------------------------------------------------------------------------

XLPE material and thickness shall be as per IEC 60502 or BS 5467 rated for 90°C continuous operation.
3. Assembly / Inner Covering

------------------------------------------------------------------------------------------------------

The inner coverings may be extruded or lapped. For cables with circular cores, except cables with more than five cores, a lapped inner covering shall be permitted only if the interstices between the cores are substantially filled. A suitable binder is permitted before application of an extruded inner covering. The material is compatible with the insulating material,The materials used for inner coverings and fillers shall be suitable for the operating temperature of the cable and compatible with the insulating material.For halogen free cables, the inner covering and fillers shall also be halogen free compound.
4. Armour

------------------------------------------------------------------------------------------------------

Aluminum/galvanized steel/steel wires applied helically over the Inner Covering as per IEC 60502-1, or double aluminum/steel tapes and copper/tinned copper wire can also be manufactured upon request.
5. Outer Sheath

------------------------------------------------------------------------------------------------------

Outer sheath shall be of extruded PVC Type ST1/ST2 as per IEC 60502-1, Polyethylene type ST3/ST7, Halogen free compound ST8, Polychloroprene, chlorosulfonated polyethylene or similar polymers, type SE1 are also available on request.
6. Fire Performance of Cable Sheaths

------------------------------------------------------------------------------------------------------

Cables can be supplied with special flame retardant PVC outer sheath to comply with the flame test requirements of IEC 60332-3-22, IEC 60332-3-23 and IEC 60332-3-24, Halogen Free material comply to IEC60754-1/2 and IEC 60684-2.

Physical and Electrical Characteristics:

No.cores x
cross-sec.
Insulation
thickness
Sheath
thickness
Nominal
value
Outer Ø
approx.
weight
approx.
Current ratings in air 30℃ Current ratings buried 20℃ maximum DC resistance at 20℃
mm² mm mm mm kg / km A A Ω/km
3×1.5 0.7 1.8 10.1 132 21 28 12.1
3×2.5 0.7 1.8 11.0 171 28 37 7.41
3×4.0 0.7 1.8 12.0 225 37 48 4.61
3×6.0 0.7 1.8 13.1 296 47 61 3.08
3×10 0.7 1.8 15.3 440 64 82 1.83
3×16 0.7 1.8 17.5 638 85 107 1.15
3×25 0.9 1.8 21.0 954 115 138 0.73
3×35 0.9 1.8 23.1 1266 140 165 0.52
3×50 1.0 1.8 23.4 1614 168 198 0.39
3×70 1.1 1.9 27.4 2264 213 242 0.27
3×95 1.1 2.0 30.6 2975 263 290 0.19
3×120 1.2 2.1 34.0 3776 307 330 0.15
3×150 1.4 2.3 38.6 4682 357 371 0.12
3×185 1.6 2.4 43.3 5802 415 418 0.10
3×240 1.7 2.6 48.1 7437 498 485 0.08
3×300 1.8 2.8 52.2 9313 575 548 0.06

INSTALLATION METHOD DETAILS

IEC 60502-1 Cables 3 core(Unarmored) | Cu-conductor / XLPE Insulated / PVC Sheathed IEC 60502-1 Cables 3 core(Unarmored) | Cu-conductor / XLPE Insulated / PVC Sheathed IEC 60502-1 Cables 3 core(Unarmored) | Cu-conductor / XLPE Insulated / PVC Sheathed IEC 60502-1 Cables 3 core(Unarmored) | Cu-conductor / XLPE Insulated / PVC Sheathed
A1 – Thermally insolated wall (Single-core) A2 – Thermally insolated wall (multi-core) B1 – Apparent electroduct (Single-core) B2 – Apparent electroduct (multi-core)
IEC 60502-1 Cables 3 core(Unarmored) | Cu-conductor / XLPE Insulated / PVC Sheathed IEC 60502-1 Cables 3 core(Unarmored) | Cu-conductor / XLPE Insulated / PVC Sheathed IEC 60502-1 Cables 3 core(Unarmored) | Cu-conductor / XLPE Insulated / PVC Sheathed IEC 60502-1 Cables 3 core(Unarmored) | Cu-conductor / XLPE Insulated / PVC Sheathed
B1 – Electroduct in brickwork (Single-core) B1 – Electroduct in brickwork (multi-core) C – On the wall  C – On the ceiling
IEC 60502-1 Cables 3 core(Unarmored) | Cu-conductor / XLPE Insulated / PVC Sheathed IEC 60502-1 Cables 3 core(Unarmored) | Cu-conductor / XLPE Insulated / PVC Sheathed IEC 60502-1 Cables 3 core(Unarmored) | Cu-conductor / XLPE Insulated / PVC Sheathed IEC 60502-1 Cables 3 core(Unarmored) | Cu-conductor / XLPE Insulated / PVC Sheathed
C – Non-perforated tray F – Perforated tray (Single-core) F – Perforated tray (multi-core) F –Suspended (Single-core)
IEC 60502-1 Cables 3 core(Unarmored) | Cu-conductor / XLPE Insulated / PVC Sheathed IEC 60502-1 Cables 3 core(Unarmored) | Cu-conductor / XLPE Insulated / PVC Sheathed IEC 60502-1 Cables 3 core(Unarmored) | Cu-conductor / XLPE Insulated / PVC Sheathed IEC 60502-1 Cables 3 core(Unarmored) | Cu-conductor / XLPE Insulated / PVC Sheathed
E – Suspended (multi-core) B2 – Construction space B2 – Construction space B1 – Electroduct (Single-core)
IEC 60502-1 Cables 3 core(Unarmored) | Cu-conductor / XLPE Insulated / PVC Sheathed IEC 60502-1 Cables 3 core(Unarmored) | Cu-conductor / XLPE Insulated / PVC Sheathed IEC 60502-1 Cables 3 core(Unarmored) | Cu-conductor / XLPE Insulated / PVC Sheathed IEC 60502-1 Cables 3 core(Unarmored) | Cu-conductor / XLPE Insulated / PVC Sheathed
B2 – Electroduct (Multi-core) B2 – Closed raceway embedded in floor (multi-core) B2 – Closed raceway embedded in floor (multi-core) B1 – Ventilated raceway embedded in floor
IEC 60502-1 Cables 3 core(Unarmored) | Cu-conductor / XLPE Insulated / PVC Sheathed IEC 60502-1 Cables 3 core(Unarmored) | Cu-conductor / XLPE Insulated / PVC Sheathed
C – Embedded in the brickwork D – Buried in additional mechanical protection

Cable Drum Data

CABLE DRUMS D1=Flange Diameter(mm) W=Useful Width (mm) D2=Barrel Diameter(mm)
IEC 60502-1 Cables 3 core(Unarmored) | Cu-conductor / XLPE Insulated / PVC Sheathed 1000 700 500
1100 700 550
1200 700 600
1400 750 710
1600 900 900
1800 1120 1000
2400 1150 1300

RECOMMENDED ORDERING PARAMETERS

CONTACT

For prompt quotation / supplies please make sure your inquiries and your orders are
securing the following data :

1 - International or Special Standard. (Alternatively, the precise usage of the cable.)
2 - Rated voltage.
3 - Copper or Aluminium conductors.
4 - Size of each conductor.
5 - Insulation material : XLPE or others.
6 - Number and identification of conductors.
7 - Other requirements.
8 - Packing.
9 - Required delivery time.
10 - Required validity.

If this all seems a litle too technical for you, then why not get in touch with us.

We look forward to assisting you in identifying the best products for your specific application and to answer any questions you might have.

Tel:+86 755 6114 5028
Fax:+86 755 61137976
E-mail : cttcable@hotmail.com
Head office:chengtiantai Industrial Park, Lisonglang community, Gongming office, Guangming district, Shenzhen P.R. China 518106

WARRANTY

For a period commencing on the date shipped the Goods to Buyer and continuing for a period of 12 months thereafter.

China IEC 60502-1 Cables 3 core(Unarmored) | Cu-conductor / XLPE Insulated / PVC Sheathed for sale

IEC 60502-1 Cables 3 core(Unarmored) | Cu-conductor / XLPE Insulated / PVC Sheathed

Inquiry Cart 0